Product name:

B6031B, B6031B2(IP54)

Product name: B6031B, B6031B2(IP54)
Listing Date: 2018-05-18

Introduction

B601, B601D series products are specially designed for water pump which are the integrated intelligent controller with superior performance and rich function, can meet the requirement of water supply in different occasions and improve the quality of water supply system to achieve the effect of energy saving and environmental protection. 


Share:
Solution / Solutions More
Views: 0
Published: 2018 - 06 - 14
When using our 3phase 220VAC output solar inverter, we recommend inputting 305V direct voltage.1) The quantity of each group solar panel(Q1) =305VDC/the direct voltage of each solar panel2) The power of each group solar panel(P1) =The power of each solar panel * The quantity of each group solar panel(Q1)3) Total number of solar panel groups(Q2)=The power of motor *1.5/The power of each group solar panel(P1)For example:About 5.5KW water pump, input 3PH 220VAC,each solar panel :250W, 60VDC, so how the Solar panel combination is ? 1) The quantity of each group solar panel(Q1)=305V/60V=5 pcs2) The power of each group solar panel(P1)=250W*5=1250W3) Total number of solar panel groups(Q2)=5500W*1.5/1250W=7 groupsIn this case, we need 5 pcs connected in series by 7 in...
Views: 0
Published: 2018 - 05 - 24
Causes of malfunctioning / Troubleshooting Countermeasures for errors⊙The system stores up to 20 information related to the detection of abnormalities.⊙To initialize the information of abnormalities saved, press the “” button for more than 1 second.If any other problems, please contact with the agent.
Views: 0
Published: 2018 - 05 - 22
Causes of malfunctioning / Troubleshooting Countermeasures for errors⊙The system stores up to 20 information related to the detection of abnormalities.⊙To initialize the information of abnormalities saved, press the “” button for more than 1 second.If any other problems, please contact with the agent.
Views: 0
Published: 2018 - 05 - 22
1.System Running Fault and Trouble Shooting2.Water supply Running Fault and Trouble ShootingFaultCodeFaultTypeReasonSolution   LP  Low Water Pressure 1. Abnormal sensor;2. Motor rotates in the reverse direction;3. Insufficient water inflow;4. There is air inside the pumpl Check the installation of pressure transmitter;l Check the motor’s direction of rotation is correct or not;l Check the parameter b01.01 (setting value too big);l Check the pump whether is vent outthe air inside HPHigh Water Pressure1. Abnormal sensor;2. The parameter b01.00 setting value is too smalll Check the installation of pressure transmitter;l Check the parameter b01.0...
  • Detailed
  • Performance
  • Applications
  • Related
  • Scheme

Specification

Single phase inputSingle phase output

 Input voltage

Single phase220V   50/60Hz

 Output power range

Single phase0~220V   0.75~2.2KW

 High quality, multi-functional, low noise and strong commonality.

 B601D series haven’t special demands to peripherals, it almost can be use the normal component. For example:

      The pressure detection output signals is 4~20mA0~5VDC

      0~10VDC Standard signal pressure transmitter.

 

Model list

Model No.

Rated Input VoltageV

House PowerHP

Rated Output CurrentA

Motor PowerKW

B601D-2001

1AC: 220V

-15%~+15%

1.0

5.3

0.75

B601D-20015

1.5

6.5

1.1

B601D-2002

2

9.6

1.5

B601D-2003

3

14

2.2

 

 

 External Dimension

The Dimension of B601D

B6031B, B6031B2(IP54) 

Dimension

Model

(kW)

A (mm)

B (mm)

H (mm)

W (mm)

D (mm)

Installation Hole

Installation Dimension

External Dimension

0.75~2.2

110

169.6

179.6

120.1

150.3

4.0


Main Features

 Sleep FunctionNo water consumption pump decelerates to the lower limit and after a detection then sleep down. Until the pressure below settings, master wake up automatically.

 Restarts After Power onPower off during running, it restarts when power on again

 Anti clogging FunctionJust designed for single pump, the pump run REV/FWD alternate.

 Day-Part ControlSplit one day into several day-part to run a private pressure respectively. Considered input side water pressure limit, once input water pressure is less than setting pressure, stop running; while up to setting, recover running.

 Terminal Run/StopCan be lead to external switch from terminal. When switch on, pump run and maintain a setting constant pressure; when switch off, pump stopped.

 Electric contact ControlTwo terminals switch on COM instruct the controller to accelerate and decelerate respectively. Can used for realize the pump running in a switch setting pressure range.

 Electrical fault protection: When there is an over current, over voltage, under voltage, phase loss, over load etc, the controller will alarm and stop automatically.



Applications

Hotel, Apartment, Residential Community area, High-rise building, Orchard, Office, Water treatment equipment etc


Related Products / Hot deals More
2018 - 05 - 18
Main Features:u Automatically control and constant water pressureu Setting pressure through keypad directlyu Auto control and constant pressure water supply.u Built-in PID control method can realize non-loaded shut down(sleep mode)u System auto-stop when no water supply and will auto-start when water supply recoveryu Running automatically when power on (Power on resta...
2018 - 05 - 18
Main Features:◆ Sleep Function:No water consumption pump decelerates to the lower limit and after a detection then sleep down. Until the pressure below settings, master wake up automatically.◆ Restarts After Power on:Power off during running, it restarts when power on again◆ Anti clogging Function:Just designed for single pump, the pump run REV/FWD alternate.◆ Day-Part Con...
2018 - 05 - 18
Main Control Function◆Control Mode: Sensorless Vector Control (SVC), V/F Control.◆Overload Capacity: 60s with 150% of rated current, 10s with 180% of rated current.◆Starting Torque: 150% of rated torque at 0.5Hz (SVC).◆Speed Adjusting Range: 1:100 (SVC).◆Speed Accuracy: ± 0.5% of maximum speed (SVC).◆Carrier Frequency: 0.5kHz ~15.0kHz. ◆Reference Frequency Source: keypad, analog inp...
2018 - 05 - 18
Main Features:◆ Intelligent integrated complete system ◆ System to match every need and requirement◆ Easy installation and operation◆ Free debugging, high efficiency,Outstanding reliability and long using life◆ Monitoring interface with touch screen◆ Multi-pump linkage, with large and small pumps