Product name:

B2000

Product name: B2000
Listing Date: 2018-05-18

Introduction

The system include complete set of water supply equipment and touch screen operating system. The users can choose the equipment from dual-pump to five pump according to the demand, including multiple pump linkage mode with same model of water pump or another model with smaller-flow pump. 



Share:
Solution / Solutions More
Views: 0
Published: 2018 - 06 - 14
When using our 3phase 220VAC output solar inverter, we recommend inputting 305V direct voltage.1) The quantity of each group solar panel(Q1) =305VDC/the direct voltage of each solar panel2) The power of each group solar panel(P1) =The power of each solar panel * The quantity of each group solar panel(Q1)3) Total number of solar panel groups(Q2)=The power of motor *1.5/The power of each group solar panel(P1)For example:About 5.5KW water pump, input 3PH 220VAC,each solar panel :250W, 60VDC, so how the Solar panel combination is ? 1) The quantity of each group solar panel(Q1)=305V/60V=5 pcs2) The power of each group solar panel(P1)=250W*5=1250W3) Total number of solar panel groups(Q2)=5500W*1.5/1250W=7 groupsIn this case, we need 5 pcs connected in series by 7 in...
Views: 0
Published: 2018 - 05 - 24
Causes of malfunctioning / Troubleshooting Countermeasures for errors⊙The system stores up to 20 information related to the detection of abnormalities.⊙To initialize the information of abnormalities saved, press the “” button for more than 1 second.If any other problems, please contact with the agent.
Views: 0
Published: 2018 - 05 - 22
Causes of malfunctioning / Troubleshooting Countermeasures for errors⊙The system stores up to 20 information related to the detection of abnormalities.⊙To initialize the information of abnormalities saved, press the “” button for more than 1 second.If any other problems, please contact with the agent.
Views: 0
Published: 2018 - 05 - 22
1.System Running Fault and Trouble Shooting2.Water supply Running Fault and Trouble ShootingFaultCodeFaultTypeReasonSolution   LP  Low Water Pressure 1. Abnormal sensor;2. Motor rotates in the reverse direction;3. Insufficient water inflow;4. There is air inside the pumpl Check the installation of pressure transmitter;l Check the motor’s direction of rotation is correct or not;l Check the parameter b01.01 (setting value too big);l Check the pump whether is vent outthe air inside HPHigh Water Pressure1. Abnormal sensor;2. The parameter b01.00 setting value is too smalll Check the installation of pressure transmitter;l Check the parameter b01.0...
  • Detailed
  • Performance
  • Applications
  • Related
  • Scheme

Operation interface

B2000B2000 

 

 

 

 

                               

 

B2000 

 

 

 

 

  

 


Specification

 Max. Flow(Q)600m³/h

 Max.Head(H): 330m

 Liquid Temp.: 0℃ to +70

 Operat.pres.: max.25bar

 Motor power: 0.75kW~15kW(Backpack Style)

 Motor power: 0.75kW~350kW(Electrical Cabinet Style)

 Pump: Up to 6 pumps

      

Definition of Model:

B2000

Model list

The selection of auxiliary pump flow is the ⅓ to ¼ of unit master pump flow and the pump model with sub-pump is in a /FX.Y form.

B2000 

B2000 


Main Features

 Intelligent integrated complete system

 System to match every need and requirement

 Easy installation and operation

 Free debugging, high efficiency,Outstanding reliability and long using life

 Monitoring interface with touch screen

 Multi-pump linkage, with large and small pumps



Applications

 Residential buildings

 Hospitals

 Office buildings

 Hotels

 Department stores

 Industry

 Other applications



Related Products / Hot deals More
2018 - 05 - 18
Main Features:u Automatically control and constant water pressureu Setting pressure through keypad directlyu Auto control and constant pressure water supply.u Built-in PID control method can realize non-loaded shut down(sleep mode)u System auto-stop when no water supply and will auto-start when water supply recoveryu Running automatically when power on (Power on resta...
2018 - 05 - 18
Main Features:◆ Sleep Function:No water consumption pump decelerates to the lower limit and after a detection then sleep down. Until the pressure below settings, master wake up automatically.◆ Restarts After Power on:Power off during running, it restarts when power on again◆ Anti clogging Function:Just designed for single pump, the pump run REV/FWD alternate.◆ Day-Part Con...
2018 - 05 - 18
Main Control Function◆Control Mode: Sensorless Vector Control (SVC), V/F Control.◆Overload Capacity: 60s with 150% of rated current, 10s with 180% of rated current.◆Starting Torque: 150% of rated torque at 0.5Hz (SVC).◆Speed Adjusting Range: 1:100 (SVC).◆Speed Accuracy: ± 0.5% of maximum speed (SVC).◆Carrier Frequency: 0.5kHz ~15.0kHz. ◆Reference Frequency Source: keypad, analog inp...
2018 - 05 - 18
Main Features:◆ Intelligent integrated complete system ◆ System to match every need and requirement◆ Easy installation and operation◆ Free debugging, high efficiency,Outstanding reliability and long using life◆ Monitoring interface with touch screen◆ Multi-pump linkage, with large and small pumps